BQTCK - KRYLON 1326 CONTACT CLEANER & LUB SPRAY

  • MSDS: BQTCK
  • Manufacturer: BORDEN CHEMICAL CO
  • Product Name: KRYLON 1326 CONTACT CLEANER & LUB SPRAY
  • National Stock Number: 9150-00N016249
Product Identification

Product ID:KRYLON 1326 CONTACT CLEANER & LUB SPRAY
MSDS Date:05/09/1989
FSC:9150
NIIN:00N016249
MSDS Number: BQTCK

Responsible Party
BORDEN CHEMICAL CO
180 E BROAD ST
COLUMBUS, OH 43215-3705
US

Emergency Phone: 614-225-6124

Info Phone: 614-225-6124

Cage: 86142

Contractor
BORDEN CHEMICAL CO
COLUMBUS, OH 43215-3705 US

Telephone: 614-225-6124

Cage: 86142

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: >70%

OSHA PEL 350 PPM;450 PPM STEL

ACGIH TLV: 350 PPM;450 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 1-5%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


TECHNIQUES MAY BE USED TO EFT MIN EMPLOYEE

RTECS: 9999999ZZ


ISOLATION & REMOTE CNTRL IN COMBINATION W/APPROP USE

RTECS: 9999999ZZ


TECHNIQUES MAY NOT NEC ADDRESS ALL ISSUES PERTAINING

RTECS: 9999999ZZ


WITH EXPERTS OF YOUR CHOICE TO DETERMINE WHETHER OR

RTECS: 9999999ZZ


AN EXHST FAN TO ENSURE FRESH AIR ENTRY DURING

RTECS: 9999999ZZ


OR DIZZ, INCR FRESH AIR, WEAR NIOSH/MSHA APPRVD RESP

RTECS: 9999999ZZ


IN AREA OF USE. DO NOT USE IN GEN VICINITY OF ARC

RTECS: 9999999ZZ


CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN ABSORP: NO HAZS KNOWN TO
BORDEN. INGESTION: NOT EXPECTED TO BE HARMFUL UNDER NORM CNDTNS OF
USE. INHAL: MAY BE HARMFUL IF INHALED. LIQ/VAP MAY CAUSE IRRIT OF
NOSE, THROAT & LUNGS. CAN CAUS E CNS DEPRESS. SKIN: MAY CAUSE IRRIT
ONPRLNGD/RPTD CONT.EYES: MAY CAUSE IRRIT ON PRLNGD/RPTD CONT. (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CHRONIC: ING 1:MAY CAUSE LIVER DMG
BASED ON ANIMAL DATA. MAY CAUSE KIDNEY DMG BASED ON ANIMAL DATA.
CAN CAUSE CNS DEPRESS. SIGNS & SYMPS MAY INCLUDE HDCH, DIZZ, NAUS,
VOMIT, UNCON & EVEN DEAT H. CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGESTION: IF ACCIDENTLY SWALLOWED, DILUTE BY DRINKING LRG
QTYS OF WATER. IMMED CONT POIS CNTRL CNTR/HOSP EMER ROOM FOR ANY
OTHER ADDNL TREATMENT DIRECTIONS. INHAL: REMOVE TO FRESH AIR. IF
NOT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. SKIN: IN CASE OF
IRRIT, FLUSH W/WATER. EYE: IMMEDIATELY FLUSH WITH PLENTY OF WATER
FOR AT LEAST 15 MINUTES. CALL PHYSICIAN IF IRRITATION PERSISTS.

Fire Fighting

Extinguishing Media:WILL NOT BURN. USE MEDIA SUITABLE FOR SURROUNDING
FIRE CONDITIONS .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . IN CASE OF FIRE, WATER SHOULD BE
USED TO KEEP FIRE-EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:CONTENTS UNDER PRESS.EXPOS TO HIGH TEMP
MAY CAUSE BURSTING. AVOID RADIATORS, STOVES, DIRECT SUNLIGHT/OTHER
HEAT SOURCE. THERM DECOMP PRODS MAY INCL HCL (SUPDAT)

Accidental Release

Spill Release Procedures:SOAK UP WITH ABSORBENT MATERIAL AND REMOVE TO
CHEMICAL DISPOSAL AREA. PREVENT ENTRY INTO NATURAL BODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE
120F. USE WITH ADEQUATE VENTILATION.
Other Precautions:HNDL I/A/W GOOD INDUS HYGIENE & SAFETY PRACTS. THESE
PRACTS INCL AVOIDING UNNEC EXPOS & REMOVAL OF MATL FROM EYES, SKIN
& CLTHG. WASH THORO AFTER HNDLG. TO AVOID BRTHG VAPS/SPRAY MIST,
OPEN WINDOWS & DOORS/USE OTHER MEANS, SUCH AS (ING 7)

Exposure Controls

Respiratory Protection:WHERE AIR CONTAMS CAN EXCEED ACCEPTABLE
CRITERIA, USE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION EQUIPMENT.
RESPIRATORS SHOULD BE SELECTED BASED ON FORM & CONC OF CONTAMS IN
AIR I/A/W OSHA 29 CFR 1910 .134 OR OTHER APPLIC STDS/GUIDELINES.
Ventilation:IF AIRBORNE CONTAMS ARE GEN WHEN MATL IS HEATED/HNDLD, SUFF
VENT IN VOL & AIR FLOW PATTERNS SHOULD BE PROVIDED (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EXPLO HAZ:& PHOSGENE . EFTS OF OVEREXP: HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS (FP N). VENT:
TO KEEP AIR CONTAM CONC LEVSBELOW ACCEPTABLE CRITERIA. ENGINEERING
CNTRLS: FOLLOWING EXPOS CNTRL (ING 3)

Chemical Properties

HCC:V6
Vapor Pres:85 PSIG
Vapor Density:HVR/AIR
Spec Gravity:HVR/H*2O
Evaporation Rate & Reference:FASTER THAN BUTYL ACETATE
Solubility in Water:SLIGHT
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:99(WT)

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY INCLUDE: CARBON MONOXIDE, CARBON
DIOXIDE, PHOSGENE AND HCL BY THERMAL DECOMPOSITION IN AIR.

Disposal

Waste Disposal Methods:INCINERATION WILL CAUSE CONTAINER TO BURST
VIOLENTLY. DISPOSE OF ACCORDING TO LOCAL, STATE/PROVINCIAL, AND
FEDERAL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.